Prodigy M2 Unit Controller Manual
1 CONTROLS Prodigy Control System Premium Rooftop Unit Control P R O D U C T S P E C I F I C AT I O N S Bulletin No April 2013 Supersedes February 2010 OVERVIEW The Prodigy Control System intelligently controls every Lennox Energence and Strategos rooftop unit. This control system provides all control functions for the unit, ensuring safe and reliable operation. Unit status information and unit diagnostics are displayed in plain English by the control system to facilitate troubleshooting.
Although default operation does not require programming, the control system has programmable parameters that allow adjustment of time delays and setpoints that enable many advanced features. The default operation requires a standard room thermostat or direct digital controller (DDC). By changing one parameter, the control system will also control the unit from a Comfort Sensor or zone temperature sensor. The Prodigy Unit Controller is a network controller when daisy chained to the L Connection Network Control System. For ease of configuration, the Prodigy Unit Controller can be connected to a PC with Unit Controller PC software installed. The Prodigy Control System is comprised of the powerful Prodigy Unit Controller and the intuitive SmartWire System.
14V60 - Unit Controller M3 Prodigy. 14V60 - Unit. Lennox Prodigy M3 Unit Controller Kit. Be the first. 59W47 - 102630-01 M2 Unit Controller Replacement Kit.
- Refer to Lennox manual 506215e_506215-01_005. Lennox Prodigy M2 board Configuration with switches and pot for Novar. To reset ECTO to. Settings – Control - L Conn Address ( Unit address for LSE), backup mode to return air sensor.
- The Prodigy Unit Controller is a network controller when daisy chained to the. The Prodigy Control System is comprised of the powerful Prodigy Unit Controller and the intuitive. Refer to “M2 BACnet Module Service Literature”, Corp. M2 LONTALK® MODULE. Refer to “Prodigy LonTalk Module Kit” Instructions.
2 FEATURES AND BENEFITS PRODIGY UNIT CONTROLLER The Prodigy Unit Controller is a microprocessor-based control board that provides flexible control of all unit functions. All control voltage is provided via a 24V (secondary) transformer with built-in circuit breaker protection.
Time Clock with Run-time Information - Internal time clock with runtime information on these key components: Power Applied Filter Blower Belt UV Lamp Blower Compressor(s) Condenser Fan(s) Heat Stage(s) Free Cooling Exhaust Fan Dehumidification The Prodigy Unit Controller features: Scrolling Display - Display scrolls full text instead of numerical codes to help simplify diagnosing and troubleshooting. The high contrast display makes it easy to read in various lighting and ambient conditions. Push Buttons - Offer simplified navigation during setup and diagnostics. Arrow buttons (no DIP switches) simplify setup and installation by making menu navigation very intuitive Guided Setup - The Prodigy Unit Controller features a guided setup procedure that speeds up and helps insure proper installation and setup of the rooftop unit. USB Port - Allows a technician or user to easily download and transfer unit information (with a time/date stamp and unit serial number) via a USB flash drive to help verify service was performed. USB drive will also allow updating software on the Prodigy Control System to obtain enhanced functionality without the need to change components.
A second USB port also offers an easy interface with a PC and the Lennox Unit Controller Software. Unit Profile - A Unit Profile can also be saved to a USB flash drive and then uploaded to an identical unit, instantly copying all setpoints. Self-Test - Unit Controller performs self-test to verify individual critical component and system performance. Included is an economizer test function that helps assure the economizer is operating correctly. Built-in functions include: Blower On/Off Delay - Adjustable time delay between blower on and off.
Built-in Control Parameter Defaults - No programming required. Compressor Time-Off Delay - Adjustable time delay between compressor shutoff and start up. DDC Compatible - Various third party DDC controllers can be factory or field installed.
Dirty Filter Switch Input - When a Dirty Filter Switch is installed, the control will signal when the indoor blower static pressure increases, indicating a dirty filter condition. Switch is optional and can be factory or field installed. Discharge Air Temperature Control - The controller will cycle up to 4 stages of heating or cooling to maintain the discharge air setpoints for heating or cooling.
Optional sensor for remote field installation in the supply duct. Display/Sensor Readout - Displays control parameters, text status messages, and sensor readings. The unit controller displays temperature readings from return air, supply air, and outdoor air sensors that are furnished as standard on all Energence units. Controller will also display readings from optional sensors such as zone sensors, CO 2 sensors or relative humidity sensors.
Economizer Control Choice - The economizer is controlled by the Prodigy Unit Controller. The control has several options for controlling the economizer.
Prodigy Control System / Page 2 3 FEATURES AND BENEFITS Fresh Air Tempering - Provides heating and cooling as needed to maintain the supply air temperature within a comfort range, regardless of the thermostat demand. Sensor ships with unit but must be field installed in the supply air duct.
Requires change to setpoint in the field to activate this mode of operation Extensive Unit Diagnostics - The Prodigy Unit Controller monitors all sensors and functions related to unit operation to provide critical information. The controller will display detailed diagnostic information with over 100 diagnostic and status messages to pinpoint any problems and reduce troubleshooting time.
All diagnostic messages and status alarms are displayed in plain English. Exhaust Fan Control Modes - Fans controlled by fresh air damper position or building static differential pressure transducer. Permanent Diagnostic Code Storage - Stores last 84 diagnostic messages even in the event of a power failure. Field Changeable Control Setpoints - Over 200 different control setpoints allow customizing of the unit operation by changing delays, cooling stages, deadbands, and other comfort control parameters.
Indoor Air Quality Input - The Prodigy Unit Controller is Demand Control Ventilation ready from the factory (optional field installed CO 2 sensor required). Two modes of operation are available: setpoint and proportional. Setpoint - Opens the economizer dampers to full position when CO 2 setpoint level is reached.
Proportional - Opens the dampers at the first set point and gradually increases it as the CO 2 level increases until the second setpoint is reached. Low Ambient Controls - Allows unit cooling operation down to 0 F. Gas Valve Time Delay Between First and Second Stage - Allows gradual increase of input rate. Minimum Compressor Run Time - Ensures proper oil return to the compressor.
Network Capable - The Prodigy Unit Controller can be daisy chained to other Energence Rooftop Units or the L Connection Network Control System using twisted pair wire. Night Setback Mode - Adjusts setpoints, closes outdoor air dampers and operates the blower on demand, may be customized for special requirements. Return Air Temperature Limit Control - Allows the user to override the demands based upon the return air temperature during either heating or cooling operation. Helps protect against abnormal operating conditions in the event of a room sensor or thermostat failure. Safety Switch Input - Normally-closed digital input allows the Prodigy Unit Controller to respond to a external safety switch trip (phase protector, low voltage, etc.) shutting down unit operation.
Service Relay Output - Digital output can indicate a critical error has occurred to an external control device. Can also be configured to energize based on relative humidity, indoor air quality, outdoor air temperature or unit operation. Smoke Alarm Mode - Control board has four choices for responding to a smoke alarm. Unit Off - unit will turn off. Positive Pressure - blower is energized, exhaust fan is de-energized, and the outdoor air dampers are opened.
Negative Pressure - blower is energized, exhaust fan is energized, and the outdoor air dampers are closed. Purge - blower is energized, exhaust fan is energized, and the outdoor air dampers are opened.
Staging - 2 heat/2 cool. Capable of up to 4 heat/4 cool with zone sensor or third party DDC control system. Strike Three Protection - Ends cooling or heating operation when any of the following occurs three times (adjustable) within a thermostat cycle: low pressure trip, high pressure trip, heat limit trip, blower proving, or freezestat trip. Gas Reheat - Control parameter option that allows simultaneous heating and cooling operation for controlling humidity for process air applications such as supermarkets.
Field installed relative humidity sensor or dehumidistat can be used. On Demand Dehumidification - Monitors and controls condenser hot gas bypass operation with Humiditrol option. Prioritizes heat and cool demand with dehumidification demand.
Reheat demand can be enabled by digital input or a field installed relative humidity sensor can be used. Thermostat Bounce Delay - Protects compressor from short cycling when mechanical thermostat is used. Warm Up Mode Delay - Adjustable time that the economizer dampers are kept in the closed position during morning warm-up. LED Indicators - For L Connection Network (transmit and receive) and for each thermostat input.
Lennox Prodigy M2 Unit Controller
PC Interface - PC with optional Unit Controller software may be used to field or remotely adjust parameters, read alarms, or display unit status. Zone Sensor Operation - Controls zone temperature with up to 4 stages of heating or cooling with optional zone sensor. Prodigy Control System / Page 3 4 FEATURES AND BENEFITS OPTIONS / ACCESSORIES Factory or Field Installed Blower Proving Switch Monitors blower operation, shuts down unit if blower fails.
Dirty Filter Switch Senses static pressure increase indicating dirty filter condition. CONTROLS OPTIONS / ACCESSORIES Factory or Field Installed Fresh Air Tempering Used in applications with high outside air requirements. The Prodigy Unit Controller energizes the first stage heat as needed to maintain a minimum supply air temperature for comfort, regardless of the thermostat demand. When ordered as a factory option, the sensor ships with the unit but must be field installed. Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return).
Power board is located in rooftop unit control box. Interoperability via BACnet or LonTalk Protocols The Prodigy control is communication compatible with third-party automation systems that support the BACnet Application Specific Controller device profile, LonMark Space Comfort Controller functional profile, or LonMark Discharge Air Controller functional profile. LonMark and the LonMark Logo are managed, granted, and used by LonMark International under a license granted by Echelon Corporation. The Lennox BACnet module has been tested and is listed with BACnet Testing Laboratories (BTL).
The LonMark 3.4 certified LonTalk module is compatible with applicable open-standard communication systems and communicates with building automation systems that support the LonMark Space Comfort Controller or Discharge Air Controller functional profiles. Commercial Control Systems L Connection Network Control System Complete building automation control system for single or multi-zone applications.
Options include local interface, software for local or remote communication, and hardware for networking other control functions. See L Connection Network Control System Product Specifications Bulletin for details. Aftermarket DDC Novar Unit Controller and options. Addiitonal aftermarket DDCs and unit controllers supported. Thermostats Control system and thermostat options. Aftermarket unit controller options. Support for 2Heat/2Cool thermostat with a generic occupancy input to control an energy saving economizer.
Field Installed Humidity Sensor Kit Humidity sensor required with factory installed Humiditrol dehumidification option or Supermarket reheat field selectable option. SMARTWIRE SYSTEM Part of the Prodigy Control System, the SmartWire System features color coded, keyed, and labeled connectors which improve and simplify unit setup. Easy connection of field sensors and accessories reduces installation and setup time. Uniform Wiring Color Scheme All Energence rooftop units have a common wiring scheme which eliminates any wiring differences between models.
If a certain color belongs to a wiring group of one Energence unit it will be the same on all other models or sizes. Labels On Wiring Connections The SmartWire System features easy to read and understand labels on all important wiring connections. This reduces installation and service time and helps assure they are wired correctly. Improved Wire Routing The SmartWire System wire routing simplifies servicing and troubleshooting by keeping it easy to trace each wire s path. BACnet is a registered trademark of ASHRAE.
ASHRAE does not endorse, approve or test prod for compliance with ASHRAE standards. Compliance of listed products to requirements of AS Standard 135 is the responsibility of the BACnet Manufactures Association (BMA).
BTL is a regi trademark of the BMA Prodigy Control System / Page 4.