Wascomat Dryer Repair Manual

Manual require that power to the dryer be disconnected, and that the device. Service manual. From factory, the dryer has been set to specific values.

  1. Wascomat Crossover Dryer Service Manual

Our online store provides you with a quick and convenient way to buy genuine Wascomat replacement parts anytime - 24 hours a day, everyday. To help us serve you better when calling the Parts Hotline, follow these simple guidelines:. Have the SERIAL NUMBER of the machine available when you call.

To identify the part number(s) of the item(s) you need, refer to the spare parts catalog for the machine. Many items in Wascomat washers and dryers have a spare part number printed on them. You may be able to identify the item(s) you need by examining the original part(s). Remember to choose a shipment method for your part(s). UPS Ground is our standard shipment method.

Expedited shipment (UPS Blue, UPS Red and UPS Saturday) are also available. Customer Care Specialists for Replacement Parts: Our staff of experienced, well-trained customer care professionals are ready to help you identify correct part numbers, then process and ship your order to any destination. We maintain a comprehensive inventory of parts to help ensure prompt delivery. Our dedicated customer care replacement parts telephone lines have minimal wait times, allowing you to spend your valuable time running your business and operating your laundry. Wascomat Genuine Replacement Parts are produced according to the manufacturer's engineering specifications. They are built for reliability, quality, long life, and are designed to work properly with the other components in the machine.

I have worked on many of the TD4545 models. I believe the control board and burner controls are the same as the TD3030. I am trying but cannot think of a control board parameter could be causing this. I assume you have other stacks at your laundry that are working fine.

I suggest swapping boards between two stacks and see if the trouble moves with the control board. FYI - I believe it is much easier to swap entire control panels between dryer. In any case if the problem is being cause by a parameter or faulty control board the problem will move with the control board. Does this issue happen with a load of clothes or when running empty as well? There are two temperature probes in each pocket.

One monitors the exhaust temperature. The other is monitoring air temperature coming from the burner leading to the tumbler. I am thinking lack of air flow or some other reason is causing the burner air temperature to spike up and shut down the burner. I am thinking the one monitoring axial temperature is taking control and shutting down the burner other then when the exhaust temperature reaches 160F. For testing purposes there are ways to prevent this thermostat from taking control. One could remove the two screws from this temperature probe and hold it outside of the air flow thus having it read room temperature. Be advised it would be very unwise to operate this way other than a test as burning of clothes would likely be the result.

I don't think a faulty burner or control is causing this issue. The Electrolux control monitoring is robust and would sure have resulted in a fault that would have been displayed at the control. Are any fault codes being displayed? - John Nery Independent Technician Tiverton RI. Original Message: Sent: 10:46 From: Richard Heighington Subject: Wascomat TD30X30 dryer problem I have a Wascomat TD 30X30 dryer that will fluctuate in temperature. It is set to 160 at high temp but will get to 150 then drop to 118 then heat to 131 and so on.

I called Wascomat and they suggested it was a programming issue in area B but I couldn't seem to be able to adjust the parameters. Has anyone else seen this problem? Richard- Richard Heighington Store Owner/ Employee Spotless Laundromats Prince George BC. Original Message: Sent: 13:11 From: John Nery Subject: Wascomat TD30X30 dryer problem I have worked on many of the TD4545 models. I believe the control board and burner controls are the same as the TD3030. I am trying but cannot think of a control board parameter could be causing this. I assume you have other stacks at your laundry that are working fine.

I suggest swapping boards between two stacks and see if the trouble moves with the control board. FYI - I believe it is much easier to swap entire control panels between dryer. In any case if the problem is being cause by a parameter or faulty control board the problem will move with the control board. Does this issue happen with a load of clothes or when running empty as well?

There are two temperature probes in each pocket. One monitors the exhaust temperature. The other is monitoring air temperature coming from the burner leading to the tumbler. I am thinking lack of air flow or some other reason is causing the burner air temperature to spike up and shut down the burner. I am thinking the one monitoring axial temperature is taking control and shutting down the burner other then when the exhaust temperature reaches 160F. For testing purposes there are ways to prevent this thermostat from taking control.

One could remove the two screws from this temperature probe and hold it outside of the air flow thus having it read room temperature. Be advised it would be very unwise to operate this way other than a test as burning of clothes would likely be the result.

I don't think a faulty burner or control is causing this issue. The Electrolux control monitoring is robust and would sure have resulted in a fault that would have been displayed at the control. Are any fault codes being displayed?

Dryer

- John Nery Independent Technician Tiverton RI. Good Morning! The symptom that you describe usually results from the temperature of the air entering the drum (from the heating system) becoming too hot. When lint accumulates in the airflow path, it slows the flow of air through the machine. This results in the inlet air temperature rising. When the air temperature reaches a certain value, the control system turns the burner off, to prevent scorching of the linen, and to prevent nuisance tripping of the high limit thermostat. A GREAT FEATURE!!!

Because the display is showing you the OUTLET air temperature from the dryer, the appearance is that the machine never reaches the programmed temperature (because the burner is being turned off on high inlet air temp). Clean lint from the airflow path, especially from atop the backdraft dampers. That should resolve your issue. Kind regards, Gary Brown- Gary Brown Manufacturer Employee Laundrylux Inwood NY. Original Message: Sent: 13:11 From: John Nery Subject: Wascomat TD30X30 dryer problem I have worked on many of the TD4545 models. I believe the control board and burner controls are the same as the TD3030. I am trying but cannot think of a control board parameter could be causing this.

I assume you have other stacks at your laundry that are working fine. I suggest swapping boards between two stacks and see if the trouble moves with the control board. FYI - I believe it is much easier to swap entire control panels between dryer. In any case if the problem is being cause by a parameter or faulty control board the problem will move with the control board. Does this issue happen with a load of clothes or when running empty as well? There are two temperature probes in each pocket.

One monitors the exhaust temperature. The other is monitoring air temperature coming from the burner leading to the tumbler. I am thinking lack of air flow or some other reason is causing the burner air temperature to spike up and shut down the burner. I am thinking the one monitoring axial temperature is taking control and shutting down the burner other then when the exhaust temperature reaches 160F. For testing purposes there are ways to prevent this thermostat from taking control. One could remove the two screws from this temperature probe and hold it outside of the air flow thus having it read room temperature. Be advised it would be very unwise to operate this way other than a test as burning of clothes would likely be the result.

I don't think a faulty burner or control is causing this issue. The Electrolux control monitoring is robust and would sure have resulted in a fault that would have been displayed at the control. Are any fault codes being displayed? - John Nery Independent Technician Tiverton RI. I will check the dampers for lint. We have cleaned the vent pipe top to bottom and the air makeup screen on the roof. But the clothes do not properly dry in these dryers and the gas turn off is at about 130 degrees but the setting says it should go to 150.

We have 50 dryers but only 2 have a problem and they are in two different dryer boxes. One upper and one lower stack.- James Radovic Owner Jupiter Laundry and Downtown Stuart Laundry Jupiter and Stuart, FL CLA Member since 2000. Original Message: Sent: 08:36 From: Gary Brown Subject: Wascomat TD30X30 dryer problem Good Morning! The symptom that you describe usually results from the temperature of the air entering the drum (from the heating system) becoming too hot. When lint accumulates in the airflow path, it slows the flow of air through the machine. This results in the inlet air temperature rising. When the air temperature reaches a certain value, the control system turns the burner off, to prevent scorching of the linen, and to prevent nuisance tripping of the high limit thermostat.

Wascomat Crossover Dryer Service Manual

A GREAT FEATURE!!! Because the display is showing you the OUTLET air temperature from the dryer, the appearance is that the machine never reaches the programmed temperature (because the burner is being turned off on high inlet air temp). Clean lint from the airflow path, especially from atop the backdraft dampers. That should resolve your issue. Kind regards, Gary Brown- Gary Brown Manufacturer Employee Laundrylux Inwood NY. Original Message: Sent: 11:46 From: James Radovic Subject: Wascomat TD30X30 dryer problem Thanks Gary. I will check the dampers for lint.

We have cleaned the vent pipe top to bottom and the air makeup screen on the roof. But the clothes do not properly dry in these dryers and the gas turn off is at about 130 degrees but the setting says it should go to 150. We have 50 dryers but only 2 have a problem and they are in two different dryer boxes. One upper and one lower stack.- James Radovic Owner Jupiter Laundry and Downtown Stuart Laundry Jupiter and Stuart, FL CLA Member since 2000. If you dryers are 12 years old they are TD3030 not TD30X30.

The E08 and E06 errors can normally be fixed by cleaning out the filter screen on the right side of the dryer after you pull out the lint screen. You also need to check the back of the dryer, after you remove the cover to be sure you clean out the lint build up there too. Once you do this you can reset the dryer and you should be good to go. I have had these problems for 10 years and can clean them in my sleep now. James Radovic Owner Jupiter Laundry and Downtown Stuart Laundry Jupiter and Stuart, FL CLA Member since 2000. Original Message: Sent: 21:31 From: Chris Markeson Subject: Wascomat TD30X30 dryer problem We are experiencing the same issue and was told by our local repairman that it was due to the screen inside the lint draw getting clogged and needing to be cleaned due to residue from fabric softener sheets. This throws an E08 code.

I am in the process of investigating what can clean the screens after 12 years of use. Any suggestions? Chris Markeson- Chris Markeson New Owner Akron OH. Original Message: Sent: 13:20 From: James Radovic Subject: Wascomat TD30X30 dryer problem If you dryers are 12 years old they are TD3030 not TD30X30.

The E08 and E06 errors can normally be fixed by cleaning out the filter screen on the right side of the dryer after you pull out the lint screen. You also need to check the back of the dryer, after you remove the cover to be sure you clean out the lint build up there too. Once you do this you can reset the dryer and you should be good to go.

I have had these problems for 10 years and can clean them in my sleep now. James Radovic Owner Jupiter Laundry and Downtown Stuart Laundry Jupiter and Stuart, FL CLA Member since 2000. I'm still having complaints that this dryer is still not heating properly even after I've cleaned the lint above the damper and anywhere else I can see. I've also swapped out the 90 degree thermostat that is located on the vertical panel in the back of the dryer. (there is another 195 degree thermostat located on a horizontal panel located on top but it's very difficult to remove the screws since there's only a few inches between it and the outer panel) Does anyone have any suggestions to solve this problem?

I guess I'll swap out the top thermostat tomorrow to eliminate that possibility. There are also two sensors that plug in next to the thermostats but I'm reluctant to replace them since they run all the way to the front of the machine and I'd have to undo all the strapping to get them out. If the thermostat swap doesn't work then I'll try changing the control board but I'll have to buy a new set of sockets since the 5.5 mm nuts are so small.- Richard Heighington Store owner Spotless Laundromats Prince George, B.C. Original Message: Sent: 11:09 From: James Radovic Subject: Wascomat TD30X30 dryer problem I would try soap and water first, then Goof Off.

Good luck on your cleaning.- James Radovic Owner Jupiter Laundry and Downtown Stuart Laundry Jupiter and Stuart, FL CLA Member since 2000 Original Message: Sent: 17:44 From: Chris Markeson Subject: Wascomat TD30X30 dryer problem James, thanks for the feedback. The side screen is now coated with a sticky residue from years of softener sheets, is there anything you know of that can safely remove that residue?- Chris Markeson Potential Investor Westfield Ctr OH. Original Message: Sent: 20:41 From: Richard Heighington Subject: Wascomat TD30X30 dryer problem I'm still having complaints that this dryer is still not heating properly even after I've cleaned the lint above the damper and anywhere else I can see. I've also swapped out the 90 degree thermostat that is located on the vertical panel in the back of the dryer. (there is another 195 degree thermostat located on a horizontal panel located on top but it's very difficult to remove the screws since there's only a few inches between it and the outer panel) Does anyone have any suggestions to solve this problem? I guess I'll swap out the top thermostat tomorrow to eliminate that possibility. There are also two sensors that plug in next to the thermostats but I'm reluctant to replace them since they run all the way to the front of the machine and I'd have to undo all the strapping to get them out.

If the thermostat swap doesn't work then I'll try changing the control board but I'll have to buy a new set of sockets since the 5.5 mm nuts are so small.- Richard Heighington Store owner Spotless Laundromats Prince George, B.C. Canada Original Message: Sent: 11:09 From: James Radovic Subject: Wascomat TD30X30 dryer problem I would try soap and water first, then Goof Off.

Good luck on your cleaning.- James Radovic Owner Jupiter Laundry and Downtown Stuart Laundry Jupiter and Stuart, FL CLA Member since 2000 Original Message: Sent: 17:44 From: Chris Markeson Subject: Wascomat TD30X30 dryer problem James, thanks for the feedback. The side screen is now coated with a sticky residue from years of softener sheets, is there anything you know of that can safely remove that residue?- Chris Markeson Potential Investor Westfield Ctr OH. Original Message: Sent: 10:46 From: Richard Heighington Subject: Wascomat TD30X30 dryer problem I have a Wascomat TD 30X30 dryer that will fluctuate in temperature. It is set to 160 at high temp but will get to 150 then drop to 118 then heat to 131 and so on. I called Wascomat and they suggested it was a programming issue in area B but I couldn't seem to be able to adjust the parameters. Has anyone else seen this problem? Richard- Richard Heighington Store Owner/ Employee Spotless Laundromats Prince George BC.

Comments are closed.