Omron Controller Manual

The next generation E5C temperature controller series is setting a new standard in terms of regulation performance easy set-up and outstanding visibility. With 3 (4) AUX outputs on board and other useful features, these slim case controllers (depth = 60mm) are fit for purpose.

Omron Controller Manual

Easy to set-up without power supply and operate intuitively via CX-Thermo software. Fast and precise regulation: 50ms sampling loop period time. Best contrast display using white LCD technology which is visible from a far distance and from any angle. Useful alarm and diagnosis functions for secure operations. Factory Mutual Approved Temperature Limit Controllers for applicable models!One of the primary concerns of every company is to protect their business (personnel, machines, etc.) from a property loss due to runaway heating or cooling systems.

To minimize or altogether eliminate property loss, companies use products that conform to the Factory Mutual standard.The E5C-600 is ideal for any application where the need to prevent a “temperature runaway” condition that can compromise operator safety, or damage equipment and product. Industrial Ovens. Furnaces. Kilns.

This manual describes the E5CN, E5CN-U, E5AN, E5EN, and E5GN. Digital Temperature Controllers User's Manual Advanced Type (Cat. Start Instruction contains only recommendations and does not substitute thorough study the user manual. It is aimed at technically skilled persons.

Omron Controller Manual

Introduction OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.

Incinerators. Boilers LCD display. Easy set-up, quick and intuitive operation Setting up the controllers is made easy by the incorporation of auto-tuning algorithms, and by Omron’s new intuitive CX-Thermo support software. This enables faster parameter setting and straightforward device adjustment as well as greatly simplifying maintenance.

E5cj Omron Controller Manual

A time saving shift key is also provided on the controller front panel to allow rapid adjustment of set values, alternatively functions like Auto- Tuning or RUN/STOP could be associated Precise control. External influences can cause the temperature to deviate from the required set value. With the E5C it is possible to program the level at which the display starts blinking. Alarm options include deviation from set point, where if the set point is changing the alarm moves with it. Absolute alarms where they are referenced to 0, standby so the alarms will not be active during the set point has been reached. Latching which means that once triggered they can only be deactivated by removing power. This is ideal for remote or unmanned processes, as the alarm will remain until the machinery is next visited.

Omron Controller

Basic (2-step) programmer In many thermal processes (food, brick, pottery etc.) a small element of timing is required. This feature enables you to ramp up to a set-point and set the dwell time period. At the end of this time, the process stops or continues with an indication alarm to alert the operator. With this feature, a fixed minimum or maximum curing/baking time is assured in a smooth, controlled way. Alternatively you can set different steepness for the ramp-down period, e.g. Allowing a soft decrease of temperature to avoid structural cracks of the heat treated object.